Stryker Biolox Ceramic Head

Stryker Trauma 6570 0 536 Stryker Biolox Delta Ceramic V40 Femoral Head 36mm O D 2 5mm Neck Esutures

Stryker Trauma 6570 0 536 Stryker Biolox Delta Ceramic V40 Femoral Head 36mm O D 2 5mm Neck Esutures

Stryker Trauma 6570 0 436 Stryker Biolox Delta Ceramic V40 Femoral Head 36mm O D 2 5mm Neck Esutures

Stryker Trauma 6570 0 436 Stryker Biolox Delta Ceramic V40 Femoral Head 36mm O D 2 5mm Neck Esutures

Stryker 6570 0 036 Stryker Biolox Delta Ceramic V40 Femoral Head 36mm

Stryker 6570 0 036 Stryker Biolox Delta Ceramic V40 Femoral Head 36mm

Stryker Hip Implant Recall Searcy Mass Tort Attorneys

Stryker Hip Implant Recall Searcy Mass Tort Attorneys

Hip Replacement Technology Dr William Sima

Hip Replacement Technology Dr William Sima

Https Www Strykermeded Com Media 2637 Restoration Anatomic Shell Surgical Technique Pdf

Https Www Strykermeded Com Media 2637 Restoration Anatomic Shell Surgical Technique Pdf

Https Www Strykermeded Com Media 2637 Restoration Anatomic Shell Surgical Technique Pdf

No code available 3191 event date 04 20 2011.

Stryker biolox ceramic head. Depending on ball head size biolox deltaheads show a much higher burst strength that results in reduced fracture rate. Biolox delta the next generation of ceramics is now available for articulation with connexion gxl our low wear fracture tough polyethylene. Strontia is included for the formation of platelets inside the matrix which support the toughness of the material. The biolox delta option ceramic head features a titanium neck sleeve designed to allow surgeons to utilize a ceramic head in either primary or revision hip arthroplasties.

As published for example in 2001 the composition of biolox delta includes sro y 2 o 3 and cr 2 o 3. We offer market leading hip replacement implants for total hip arthroplasty including our primary and revision portfolios designed to offer you a wide variety of implants instrumentation and muscle sparing surgical approach options. The stryker rejuvenate line extended the combined head neck length options for the rejuvenate and was intended for use with any currently available howmedica osteonics acetabular components v40 femoral heads cocr c taper alumina heads ceramic when used with the v40 c taper adaptor and the biolox delta ceramic universal taper heads and sleeves. Biolox delta is a zirconia toughened alumina ceramic zta for biomedical applications.

Below you will find an overview of the available sizes and many combination possibilities. Science behind the material. 1 4 this material also provides a new option for using a ceramic femoral head in a revision scenario with the biolox option. Accolade ii s morphometric wedge is designed to address modern demands with novel technology by evolving conventional tapered wedge femoral stem design with size specific medial curvature to more closely fit a broad range of bone sizes and shapes of today s patient population.

Trident alumina ceramic inserts. Stryker biolox delta ceramic v40 femoral head. Device problems material erosion 1214. The trident alumina ceramic inserts must be used with stryker orthopaedic alumina heads.

Device dislodged or dislocated 2923 patient problems hematoma 1884. Biolox forte and biolox delta ball heads and cup inserts can be combined with ceramic components from the biolox family of products as well as with inserts made from conventional and highly cross linked polyethylene. Model number 28 mm. For 28 mm ball heads which generally have the lowest burst strength there is a burst strength increase from 54 to 80 for biolox delta.

Event type malfunction event description. Rotational stability between the components can be achieved when the shell s anti rotational barbs interlock with the insert scallops.

A Ceramic On Ceramic Prosthesis Note The Small Head Diameter Stryker Download Scientific Diagram

A Ceramic On Ceramic Prosthesis Note The Small Head Diameter Stryker Download Scientific Diagram

Http Www Rpa Spot Pt Getdoc 66784c08 674d 404a A83a B83762546be9 Lift Anatomic Big Heads On Pe Acetabular System Aspx

Http Www Rpa Spot Pt Getdoc 66784c08 674d 404a A83a B83762546be9 Lift Anatomic Big Heads On Pe Acetabular System Aspx

Trident1 Acetabular System From Stryker Orthopaedics Mahwah Nj Download Scientific Diagram

Trident1 Acetabular System From Stryker Orthopaedics Mahwah Nj Download Scientific Diagram

Trident Acetabular System Hemispherical Surgical Protocol Pdf Free Download

Trident Acetabular System Hemispherical Surgical Protocol Pdf Free Download

Stryker Meded

Stryker Meded

Clinically Proven Fiber Metal Material Power To Choose Advanced Bearing Technologies To Match Patient Demands Pdf Free Download

Clinically Proven Fiber Metal Material Power To Choose Advanced Bearing Technologies To Match Patient Demands Pdf Free Download

Http Cdn Stryker Com Sykgcsdoc 2 49552 Pdf

Http Cdn Stryker Com Sykgcsdoc 2 49552 Pdf

On Poly Vs Metal On Poly

On Poly Vs Metal On Poly

Revision Surgical Technique Pdf Free Download

Revision Surgical Technique Pdf Free Download

Http Cdn Stryker Com Sykgcsdoc 2 45343 Pdf

Http Cdn Stryker Com Sykgcsdoc 2 45343 Pdf

9hmtoljpljcsgm

9hmtoljpljcsgm

Http Www Bizwan Com Mydoc Stryker Hip 037 20restoration 20modular 20revision 20hip 20system 20surgical 20protocol 20 20milled 20body Fluted 20 20plasma Pdf

Http Www Bizwan Com Mydoc Stryker Hip 037 20restoration 20modular 20revision 20hip 20system 20surgical 20protocol 20 20milled 20body Fluted 20 20plasma Pdf

Home

Home

Kit Lookup Boost Toolkit

Kit Lookup Boost Toolkit

Source : pinterest.com