Superflat Floor Construction

Building floors to very high tolerances can be very time consuming.
Superflat floor construction. Superflat floors are constructed to far tighter tolerances than conventional floor slabs using a specialized tolerance system call the fmin f minimum tolerance system. Constructing superflat floors starts on the drawing board. Ligchine screedsaver max with paver superflat combo head running on in floor heat tubing duration. Great care and consideration is given to optimize the local materials to obtain the best possible concrete mix design with emphasis on finishability and durability.
This is based on defining a floor s maximum variation for a certain lift truck. Initial levelling of super flat concrete floor. Superflat is responsible for the development and launch of industry wide adopted processes including the st115. The fmin system is based upon defining the maximum variation in a floor surface for a particular lift truck.
Fsf superflat floors are constructed in narrow strips to ensure that the highest degree of flatness is achieved for the defined traffic specification. Optimizing the floor surface simply optimizes the performance of the lift truck operation. Beware of specifications for random traffic floors when superflat defined traffic tolerances are needed there are two basic floor categories. Floor flatness issues in high speed vna warehouses any very narrow aisle warehouse floor needs to be three to four times flatter than conventional concrete floors.
Superflat floors are not superflat in all directions. Therefore upon floor installation the flatness and levelness in the future lift truck wheel tracks need to be corrected in order to improve truck rideability. They require specialized construction methods and cost more to build than floors in standard warehouses lightly trafficked industrial buildings or commercial office buildings. However the high tolerance fastrack superflat laser screed laser grind solution removes the flooring works off the critical path.
Ligchine international 7 001 views. Once the roof and walls are built we can construct up to 1 500m2 of fm2 ground supported floor per day making short work of large floor areas. A superflat floor is built to a much tighter tolerance than a normal floor slab using a special tolerance system called the fmin tolerance system. Without a proposed racking layout the floor cannot be designed or constructed to be superflat as the floor will only be superflat within the aisles and in the direction the vna forklift truck will travel.
This industry standard revolutionized the way the concrete construction world understands and perfects concrete floor finishing.