Supply Lines Through Floor With No Shutoff

Compression inlet brasscraft speedi plumb plus 3 8 in.
Supply lines through floor with no shutoff. I wouldn t go through the floor in seattle in less there was no other way. Angle valves are used on supply lines that come from the wall. Drain the water lines. When the water pipe enters the sink cabinet through the back wall a right angle stop valve is required to make the 90 degree turn to the faucet.
Use the special transition fittings shown left to transition from copper cpvc or steel. You just have to deal with them when cleaning like going around that small tree when you mow the lawn. Female iron pipe outlet x 30 in. Brasscraft speedi plumb plus 3 8 in.
On a straight stop valve the inlet and outlet are aligned. Of length flexible braided polymer water connector is corrosion resistant inside and out. Shut off valve types also differ by configuration. That 3 piece with go through a small hole in the wall with the escutcheon and shutoff valve.
There are two styles of compression valve commonly used in sink hookups. Compression inlet x 1 2 in. Or you could loop some pex in there too. For pricing and availability.
Straight valves are typically found where the supply line comes through the floor. Make sure you shut off the main water supply then drain the lines. These heights are compatible with most common vanity sinks. Be sure to leave extra pipe on both ends of the run.
Before you remove the toilet shut off valve you ll need to drain the supply line to prevent the water remaining in the pipe from gushing out onto your bathroom floor. Sharkbite brass 1 2. Flexible supply lines make that moot which is why all roughs are on the wall now. Secure the line to the joists using clamps image 2.
Water supply lines are usually just a couple of inches higher between 20 and 22 inches from the floor and installed one to each side of the drain line. For more information on pipe transitions see how to join dissimilar pipes. Used to connect the water supply to your faucet this connector features a high tenacity multi filament yarn protected by a special polymer coating for. On an angle valve the outlet is at a 90 degree angle from the supply line.
That way you aren t soldering in the wall. Sink drain lines are typically between 18 and 20 inches above the finished floor. Solder glue or thread on the transition fitting then crimp pex line on the barbed fitting. Sharkbite brass 1 2 in push to connect x 3 8 in od compression quarter turn angle valve.
Pull the lines up through the holes drilled in the sub floor image 1 and then run the other end to the area where the water will be coming into the home. For pricing and availability.