Swing Door Floor Clearance Requirements

Section 404 of the ada states.
Swing door floor clearance requirements. 603 2 3 door swing doors shall not swing into the clear floor space or clearance required for any fixture. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop with the door open 90 degrees the clear width. Clear width door openings shall provide a clear width of 32 inches minimum and a maximum of 48 inches. Door openings shall provide a clear width of 32 inches 815 mm minimum.
Devices that depend on the release of. The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements. Can doors swing into the turning space and fixture clearances. Yes doors can swing into turning space.
Clear floor space at controls must be located outside the door swing to prevent users from getting hit by the door. Doors shall be permitted to swing into the required turning space. Each leaf of the pair shall be provided with its own releasing device. They cannot swing into the clearance required at plumbing fixtures except in single user toilet rooms where clear floor space 30 minimum by 48 minimum is provided in the room beyond the arc of the door swing 603 2 3 ex.
Hinge side approaches a side approach toward the hinge side of the door to the pull side of swinging doors shall have maneuvering space that extends 36 inches 915 mm minimum beyond the latch side of the door if 60 inches 1525 mm minimum is provided perpendicular to the doorway or maneuvering space that extends 42 inches 1065 mm minimum beyond the latch side of the door if 54 inches 1370 mm minimum is provided perpendicular to the doorway. Clear floor space required at tactile signs which must be beyond the arc of any door swing between the closed position and 45 degree open position 703 4 2 dressing fitting or locker rooms unless wheelchair space is provided beyond the arc of the door swing 803 3 in other locations doors can swing into clear floor or ground space although locating door swing outside required clearances is advisable. Clear floor space at door control must be located outside door swing. Door and gate controls must be compliant as operable parts operable with one hand and without tight grasping pinching twisting of the wrist or more than 5 lbf.
Openings more than 24 inches deep shall provide a clear opening of 36 inches minimum. Requires the latch or lock to be located not less than 34 nor more than 48 above the floor. In general the requirements are a minimum of 32 in width and a maximum of 48 and the door must open to 90 degrees. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop with the door open 90 degrees.